Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf breaker type) -FDB:2and3pole600V -FD:1,2(277V)and3pole(600V) -HFD:1,2(277V)and3pole(600V)EHD:1,2(277V)and3pole(480V)Main Breaker Trip Ratings2 and 3 pole (contact factory for single phase sizes B, C, D) • Size B, C: 15 to 100 amps • Size D, F: 15 to 225 ampsMain LugsSize B, C, F: 225 amps • Size D: not available; main breaker onlyAmpere Interrupting CapacityAll size panels are certified to 10kAIC • Breaker AIC ratings:GHBbreaker:14kAICat480Y/277EHDbreaker:14kAICat480VBreaker types optional with sizes B, C and D panel only:GDBbreaker:14kAICat480VBreaker types optional with size F panel only:FDBbreaker:14kAICat480Vand600V -FDbreaker:18kAICat600Vand35kAICat480Vand277V -HFDbreaker:25kAICat600Vand65kAICat480Vand277VD2L/EPL Series:Branch Breakers (120/240 VAC BAB Series Quicklag® Bolt-on) Trip Ratings
39
train
164,705
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Circuit breaker operators – D2D/EXD size F: copper-free aluminum; all other types: non-metallicCircuit breaker operators – D2D/EXD size F: copper-free aluminum; all other types: non-metallicTo accommodate up to 100 amp branch loads (only 3 circuits); balance is up to 50 ampsTo accommodate up to 100 amp branch loads (only 3 circuits); balance is up to 50 ampsCertifications and Compliances:Lifting bracket – electrogalvanized cold rolled steel • Chassis – silver-plated copper • Breather cap – Delrin® non-metallic material • Neutral and ground bar – tin-plated aluminumEXD & EPL Series (Division 1): • NEC/CEC:Class I, Division 1 & 2, Groups B†, C, DClass I, Zone 1 & 2, IIB + H2† Class II, Division 1, Groups E, F, GClass II, Division 2, Groups F, GClass IIINEMA/EEMAC:3,4,4X*,7B†CD,9EFG,12CSAEnc.3,4,5ULStandard:67,1203cUL(toCSAStandardC22Nos.29&30)IP65D2D & D2L Series (Division 2): • NEC/CEC:Class I, Division 2, Groups B†, C, D
39
train
164,706
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Class I, Zone 2, IIB + H2† Class II, Division 2, Groups F, GClass IIINEMA/EEMAC:3,4,4X*,7B†CD,12CSAEnc.3,4,5ULStandard:67,1203cUL(toCSAStandardC22.2Nos.29&30)IP65D2DDS†Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix GB. For field installable kit, order EPL-GB-KIT for D2L/EPL or EXD-GB-KIT for D2D/EXD sizes B, C and D separately.NEMA4XratingisavailablewhenorderedwithsuffixS752orS753.Delrin® is a registered trademark of DuPont.6EATON’s crOusE-hiNds PowerPlus™ PanelboardsMain Breaker AmperageBranch Breaker3P 4WUp to 100G-frameB3P 3WUp to 100G-frame3P 4WUp to 100G-frameC3P 3WUp to 100G-frameD480Y/277 480Δ13P 4W3P 3WUp to 225Up to 225G-frameG-frameF480Y/277, 480Δ or 600Δ13P 3W or 3P 4W Up to 225F-framePanel Sizes B, C and D (GHB Series Cutler-Hammer™)
39
train
164,707
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 1,2and3pole:GHB480/277Y(standardoffering) • 2and3pole:GDB480Δ (requires suffix GDB) • 1,2and3pole:GBH600Y/347(requires suffix GBH; contact factory)1,2and3pole:GHB480/277Y(standardoffering) • 2and3pole:GDB480Δ (requires suffix GDB) • 1,2and3pole:GBH600Y/347(requires suffix GBH; contact factory)15,20,25,30,35,40,45,50amp(availableinallbreakerspaces inpanel);60,70,80,90,100amp(only3breakerspaces 3 available)15,20,25,30,35,40,45,50amp(availableinallbreakerspaces inpanel);60,70,80,90,100amp(only3breakerspaces 3 available)Ambient compensated breakers are optional to +50°C (suffix V)Panel Size F (F-frame breaker: EHD Cutler-Hammer standard)15,20,25,30,35,40,45,50,60,70amp(availableinallbreaker spacesinpanel);80,90,100amp(only3breakerspacesavailable) 2 • Breaker types available (refer to Options section to specify15,20,25,30,35,40,45,50,60,70amp(availableinallbreaker spacesinpanel);80,90,100amp(only3breakerspacesavailable) 2 • Breaker types available (refer to Options section to specify
39
train
164,708
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf breaker type) -FDB:2and3pole600V -FD:1,2(277V)and3pole(600V) -HFD:1,2(277V)and3pole(600V)EHD:1,2(277V)and3pole(480V)Main Breaker Trip Ratings2 and 3 pole (contact factory for single phase sizes B, C, D) • Size B, C: 15 to 100 amps • Size D, F: 15 to 225 ampsMain LugsSize B, C, F: 225 amps • Size D: not available; main breaker onlyAmpere Interrupting CapacityAll size panels are certified to 10kAIC • Breaker AIC ratings:GHBbreaker:14kAICat480Y/277EHDbreaker:14kAICat480VBreaker types optional with sizes B, C and D panel only:GDBbreaker:14kAICat480VBreaker types optional with size F panel only:FDBbreaker:14kAICat480Vand600V -FDbreaker:18kAICat600Vand35kAICat480Vand277V -HFDbreaker:25kAICat600Vand65kAICat480Vand277VD2L/EPL Series:Branch Breakers (120/240 VAC BAB Series Quicklag® Bolt-on) Trip Ratings
39
train
164,709
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 1201 Wolf Street Syracuse,NY13208(866)764-5454 FAX:(315)477-5179 FAX Orders Only: (866)653-0640crouse.customerctr@ cooperindustries.comFor more information:If further assistance is required, please contact an authorized Eaton Distributor, Sales Office, or Customer Service Department.Canada TollFree:800-265-0502 FAX:(800)263-9504 FAXOrdersonly:(866)653-0645Mexico/Latin America/Caribbean 52-555-804-4000 FAX:52-555-804-4020 mxmercadotecnia@ cooperindustries.comEurope (Germany) 49(0)6271806-500 49(0)6271806-476 sales.CCH.de@ cooperindustries.comEaton's Crouse-Hinds 1201 Wolf Street Syracuse,NY13208 Crouse-Hinds.comEaton 1000 Eaton Boulevard Cleveland,OH44122 UnitedStates Eaton.com©2014Eaton All Rights Reserved PrintedinUSA PublicationNo.5140-0714 July2014Middle East (Dubai) 97144272500 FAX:97144298521 sales.CCH.me@ cooperindustries.comSingapore 65-6645-9888 FAX:65-6297-4819 chsi-sales@ cooperindustries.comChina 86-21-2899-3600 FAX:86-21-2899-4055 cchsales@ cooperindustries.com
39
train
164,724
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Eaton is a registered trademark.All other trademarks are property of their respective owners.Korea 82-2-3484-6783 82-2-3484-6778 CCHK-sales@ cooperindustries.comAustralia 61-2-8787-2777 FAX:61-2-9609-2342 CEASales@ cooperindustries.comIndia 91-124-4683888 FAX:91-124-4683899 cchindia@ cooperindustries.com
39
train
164,725
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Provides superior protection of enclosed wiring against water and corrosionProvides superior protection of enclosed wiring against water and corrosionCast aluminum enclosures are also gasketed, providing a NEMA 4 watertight sealCast aluminum enclosures are also gasketed, providing a NEMA 4 watertight seal316L STAINLESS STEEL TERMINAL HOUSINGPowerPlus panelboards offer an industrial grade 316L stainless steel terminal housing as standardPowerPlus panelboards offer an industrial grade 316L stainless steel terminal housing as standardDesign offers an increased internal volume with a removable front cover for easy access during field installation and maintenanceD2LBS (Inverted) or D2DBS (Inverted)A cast aluminum terminal housing is standard on EPL and EXD panels and available on D2L and D2D panelsA cast aluminum terminal housing is standard on EPL and EXD panels and available on D2L and D2D panels†Not available in size F offering. Spring aligning forks are standard on size F panels.
39
train
164,728
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf ‡EPL*A and EXD*A conduit entries 2" or larger in Class I, Division 1 must be sealed within 18" of enclosure. All alternate feed entries to breaker housing (suffix A) must have an external seal within 18" of enclosure.EATON’s crOusE-hiNds PowerPlus™ Panelboards5SpecificationsPowerPlus factory sealed panelboards are premium panelboards that provide maximum circuit flexibility with labor savings during installation, operation and maintenance, and are accommodating for future changes in the field (order with either ‘S’ or ‘A’ in base catalog number). Panels are pre-wired to maximum circuit capacity, allowing for easy and safe replacement or installation of components in the field, while maintaining factory sealed integrity.
39
train
164,729
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf PowerPlus non-factory sealed panelboards are value panelboards that offer maximum circuit flexibility and many of the same features of the PowerPlus premium line. This value solution is provided without terminal housing and factory wiring of circuits (order with ‘N’ in base catalog number). The non-factory sealed solution reduces initial panelboard material costs and requires field wiring to circuit breakers and external seals to be field installed during installation.Branch circuit (1, 3, 5) wire rangeBranch circuit (balance) wire rangeNeutral line wire rangeNeutral circuit wire range4-4/010-024-86-350MCM14-46-350MCM10-018-46-250MCM14-1/0Ground line wire range6-350MCM6-250MCMApplications:Ground circuit wire range14-414-1/0Areas made hazardous by the continuous or abnormal presence of flammable gases, vapors and combustible dusts • Areas subject to weather, dampness and corrosion • For branch power distribution and circuit protection to motors,
39
train
164,730
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Areas made hazardous by the continuous or abnormal presence of flammable gases, vapors and combustible dusts • Areas subject to weather, dampness and corrosion • For branch power distribution and circuit protection to motors,valves, pumps, lighting, heat tracing, receptacles, etc.For indoor and outdoor applications in petroleum refineries, chemical and petrochemical plants and other process industry facilities where similar hazards existFor indoor and outdoor applications in petroleum refineries, chemical and petrochemical plants and other process industry facilities where similar hazards existGasket – neoprene (cast aluminum enclosure); foam-in-place (stainless steel enclosure)Gasket – neoprene (cast aluminum enclosure); foam-in-place (stainless steel enclosure)Operating handles – copper-free aluminum • Operating shafts and bushings, cover bolts, washers, hinges, breather/drain, retractile springs – stainless steel
39
train
164,731
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Operating handles – copper-free aluminum • Operating shafts and bushings, cover bolts, washers, hinges, breather/drain, retractile springs – stainless steelCircuit breaker operators – D2D/EXD size F: copper-free aluminum; all other types: non-metallic
39
train
164,732
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Provides superior protection of enclosed wiring against water and corrosionProvides superior protection of enclosed wiring against water and corrosionCast aluminum enclosures are also gasketed, providing a NEMA 4 watertight sealCast aluminum enclosures are also gasketed, providing a NEMA 4 watertight seal316L STAINLESS STEEL TERMINAL HOUSINGPowerPlus panelboards offer an industrial grade 316L stainless steel terminal housing as standardPowerPlus panelboards offer an industrial grade 316L stainless steel terminal housing as standardDesign offers an increased internal volume with a removable front cover for easy access during field installation and maintenanceD2LBS (Inverted) or D2DBS (Inverted)A cast aluminum terminal housing is standard on EPL and EXD panels and available on D2L and D2D panelsA cast aluminum terminal housing is standard on EPL and EXD panels and available on D2L and D2D panels†Not available in size F offering. Spring aligning forks are standard on size F panels.
39
train
164,738
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf ‡EPL*A and EXD*A conduit entries 2" or larger in Class I, Division 1 must be sealed within 18" of enclosure. All alternate feed entries to breaker housing (suffix A) must have an external seal within 18" of enclosure.EATON’s crOusE-hiNds PowerPlus™ Panelboards5SpecificationsPowerPlus factory sealed panelboards are premium panelboards that provide maximum circuit flexibility with labor savings during installation, operation and maintenance, and are accommodating for future changes in the field (order with either ‘S’ or ‘A’ in base catalog number). Panels are pre-wired to maximum circuit capacity, allowing for easy and safe replacement or installation of components in the field, while maintaining factory sealed integrity.
39
train
164,739
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf PowerPlus non-factory sealed panelboards are value panelboards that offer maximum circuit flexibility and many of the same features of the PowerPlus premium line. This value solution is provided without terminal housing and factory wiring of circuits (order with ‘N’ in base catalog number). The non-factory sealed solution reduces initial panelboard material costs and requires field wiring to circuit breakers and external seals to be field installed during installation.Branch circuit (1, 3, 5) wire rangeBranch circuit (balance) wire rangeNeutral line wire rangeNeutral circuit wire range4-4/010-024-86-350MCM14-46-350MCM10-018-46-250MCM14-1/0Ground line wire range6-350MCM6-250MCMApplications:Ground circuit wire range14-414-1/0Areas made hazardous by the continuous or abnormal presence of flammable gases, vapors and combustible dusts • Areas subject to weather, dampness and corrosion • For branch power distribution and circuit protection to motors,
39
train
164,740
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Areas made hazardous by the continuous or abnormal presence of flammable gases, vapors and combustible dusts • Areas subject to weather, dampness and corrosion • For branch power distribution and circuit protection to motors,valves, pumps, lighting, heat tracing, receptacles, etc.For indoor and outdoor applications in petroleum refineries, chemical and petrochemical plants and other process industry facilities where similar hazards existFor indoor and outdoor applications in petroleum refineries, chemical and petrochemical plants and other process industry facilities where similar hazards existGasket – neoprene (cast aluminum enclosure); foam-in-place (stainless steel enclosure)Gasket – neoprene (cast aluminum enclosure); foam-in-place (stainless steel enclosure)Operating handles – copper-free aluminum • Operating shafts and bushings, cover bolts, washers, hinges, breather/drain, retractile springs – stainless steel
39
train
164,741
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Operating handles – copper-free aluminum • Operating shafts and bushings, cover bolts, washers, hinges, breather/drain, retractile springs – stainless steelCircuit breaker operators – D2D/EXD size F: copper-free aluminum; all other types: non-metallic
39
train
164,742
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Options:To add the following features to the panelboard, add a space and thenthesuffixtothecatalognumber.Multiplesuffixesshouldbe added in alpha-numeric order.
39
train
164,743
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Space heater (D2L/EPL) .................................................................. R22 Space heater (D2D/EXD) ................................................................ R44 5 .....................................SP Square head plugs on all conduit openings Epoxy powder coat finish, external .............................................. S752 Epoxy powder coat finish, internal and external ........................... S753 ....................................RP Recess head plugs on all conduit openings Stainless steel breaker operator cover (ice shield) .......................... HG Group B kit factory installed ............................................................ GB ......................................................................................G GFI breakers 67 EPD breakers .................................................................................. E 6 HID breakers .....................................................................................H Ambient compensated
39
train
164,744
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf breakers (+50ºC) ...........................................V 8 GDB480Δ 3P 3W system ............................................................GDB FDB600Vbreakers ................................................................ FDB600 9 FD600Vbreakers ......................................................................FD600 9 HFD600Vbreakers ................................................................ HFD600 Lamacoid nameplate .......................................................................LID
39
train
164,745
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 569A standard panelboard has conduit openings for power and branch circuits on top.Toorderapanelboardwithmainpowerfeedfromthebottomof breaker housing, and branch entries on top (alternate), add ....... A10Toorderapanelboardwithmainpowerfeedfromthebottomof breaker housing, and branch entries on top (alternate), add ....... A10Toorderaninvertedpanelboardwithallconduitopeningsfor power and branch circuits on the bottom (inverted), add ................ IToorderaninvertedpanelboardwithallconduitopeningsfor power and branch circuits on the bottom (inverted), add ................ IToorderaninvertedpanelboardwithmainpowerfeedontopand bottom (alternate inverted), add ................................................A-I104The weight of the panel is sufficiently supported by mounting of breaker enclosure.
39
train
164,746
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 5 Not available on stainless terminal housings. 6Available with D2L and EPL panels only. For D2D/EXD, please contact factory. 7 positionsforsinglepoleEPD:oddsstartatposition1;evensstartatposition4. 8Singlepole480VEPDavailable.Forallothers,pleasecontactfactory.TwobreakerAvailable in D2D and EXD sizes B, C and D only. 9Available with D2D and EXD size F panels only. 10 Not available in D2L/EPL size D panels. D2D/EXD sizes C and D are only available withupto36circuits.Breaker Spaces TablesTable A. Maximum Number of Breaker Spaces D2L/EPL PanelsMaximum Number of Branch circuit Breaker spacesPanel sizeWith Main Lug OnlyWith Main BreakerTwo PoleThree PoleAvailable Main Breaker AmpacityAvailable with GFi, EPd Branch ProtectionB242221Up to 10012Yes11 C4240363936Up to 10012110 to 22513YesYesD424242Up to 22513YesTable B. Maximum Number of Breaker Spaces D2D/EXD PanelsMaximum Number of Branch circuit Breaker spacesPanel size
39
train
164,747
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf With Main Lug OnlyWith Main BreakerTwo PoleThree PoleAvailable Main Breaker AmpacityAvailable with GFi, EPd Branch Protection14B242221Up to 10012NoC424039Up to 10012NoDN/A4242Up to 22513NoF303030Up to 22513NoTable C. To Size Panels with GFI or EPD Branch BreakersMaximum Number of GFi or EPd BreakersPanel sizeWith Main Lug or Main Breakersingle PoleTwo PoleB2112
39
train
164,748
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Options:To add the following features to the panelboard, add a space and thenthesuffixtothecatalognumber.Multiplesuffixesshouldbe added in alpha-numeric order.
39
train
164,749
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Space heater (D2L/EPL) .................................................................. R22 Space heater (D2D/EXD) ................................................................ R44 5 .....................................SP Square head plugs on all conduit openings Epoxy powder coat finish, external .............................................. S752 Epoxy powder coat finish, internal and external ........................... S753 ....................................RP Recess head plugs on all conduit openings Stainless steel breaker operator cover (ice shield) .......................... HG Group B kit factory installed ............................................................ GB ......................................................................................G GFI breakers 67 EPD breakers .................................................................................. E 6 HID breakers .....................................................................................H Ambient compensated
39
train
164,750
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf breakers (+50ºC) ...........................................V 8 GDB480Δ 3P 3W system ............................................................GDB FDB600Vbreakers ................................................................ FDB600 9 FD600Vbreakers ......................................................................FD600 9 HFD600Vbreakers ................................................................ HFD600 Lamacoid nameplate .......................................................................LID
39
train
164,751
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 569A standard panelboard has conduit openings for power and branch circuits on top.Toorderapanelboardwithmainpowerfeedfromthebottomof breaker housing, and branch entries on top (alternate), add ....... A10Toorderapanelboardwithmainpowerfeedfromthebottomof breaker housing, and branch entries on top (alternate), add ....... A10Toorderaninvertedpanelboardwithallconduitopeningsfor power and branch circuits on the bottom (inverted), add ................ IToorderaninvertedpanelboardwithallconduitopeningsfor power and branch circuits on the bottom (inverted), add ................ IToorderaninvertedpanelboardwithmainpowerfeedontopand bottom (alternate inverted), add ................................................A-I104The weight of the panel is sufficiently supported by mounting of breaker enclosure.
39
train
164,752
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 5 Not available on stainless terminal housings. 6Available with D2L and EPL panels only. For D2D/EXD, please contact factory. 7 positionsforsinglepoleEPD:oddsstartatposition1;evensstartatposition4. 8Singlepole480VEPDavailable.Forallothers,pleasecontactfactory.TwobreakerAvailable in D2D and EXD sizes B, C and D only. 9Available with D2D and EXD size F panels only. 10 Not available in D2L/EPL size D panels. D2D/EXD sizes C and D are only available withupto36circuits.Breaker Spaces TablesTable A. Maximum Number of Breaker Spaces D2L/EPL PanelsMaximum Number of Branch circuit Breaker spacesPanel sizeWith Main Lug OnlyWith Main BreakerTwo PoleThree PoleAvailable Main Breaker AmpacityAvailable with GFi, EPd Branch ProtectionB242221Up to 10012Yes11 C4240363936Up to 10012110 to 22513YesYesD424242Up to 22513YesTable B. Maximum Number of Breaker Spaces D2D/EXD PanelsMaximum Number of Branch circuit Breaker spacesPanel size
39
train
164,753
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf With Main Lug OnlyWith Main BreakerTwo PoleThree PoleAvailable Main Breaker AmpacityAvailable with GFi, EPd Branch Protection14B242221Up to 10012NoC424039Up to 10012NoDN/A4242Up to 22513NoF303030Up to 22513NoTable C. To Size Panels with GFI or EPD Branch BreakersMaximum Number of GFi or EPd BreakersPanel sizeWith Main Lug or Main Breakersingle PoleTwo PoleB2112
39
train
164,754
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Options:To add the following features to the panelboard, add a space and thenthesuffixtothecatalognumber.Multiplesuffixesshouldbe added in alpha-numeric order.
39
train
164,755
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Space heater (D2L/EPL) .................................................................. R22 Space heater (D2D/EXD) ................................................................ R44 5 .....................................SP Square head plugs on all conduit openings Epoxy powder coat finish, external .............................................. S752 Epoxy powder coat finish, internal and external ........................... S753 ....................................RP Recess head plugs on all conduit openings Stainless steel breaker operator cover (ice shield) .......................... HG Group B kit factory installed ............................................................ GB ......................................................................................G GFI breakers 67 EPD breakers .................................................................................. E 6 HID breakers .....................................................................................H Ambient compensated
39
train
164,756
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf breakers (+50ºC) ...........................................V 8 GDB480Δ 3P 3W system ............................................................GDB FDB600Vbreakers ................................................................ FDB600 9 FD600Vbreakers ......................................................................FD600 9 HFD600Vbreakers ................................................................ HFD600 Lamacoid nameplate .......................................................................LID
39
train
164,757
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 569A standard panelboard has conduit openings for power and branch circuits on top.Toorderapanelboardwithmainpowerfeedfromthebottomof breaker housing, and branch entries on top (alternate), add ....... A10Toorderapanelboardwithmainpowerfeedfromthebottomof breaker housing, and branch entries on top (alternate), add ....... A10Toorderaninvertedpanelboardwithallconduitopeningsfor power and branch circuits on the bottom (inverted), add ................ IToorderaninvertedpanelboardwithallconduitopeningsfor power and branch circuits on the bottom (inverted), add ................ IToorderaninvertedpanelboardwithmainpowerfeedontopand bottom (alternate inverted), add ................................................A-I104The weight of the panel is sufficiently supported by mounting of breaker enclosure.
39
train
164,758
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 5 Not available on stainless terminal housings. 6Available with D2L and EPL panels only. For D2D/EXD, please contact factory. 7 positionsforsinglepoleEPD:oddsstartatposition1;evensstartatposition4. 8Singlepole480VEPDavailable.Forallothers,pleasecontactfactory.TwobreakerAvailable in D2D and EXD sizes B, C and D only. 9Available with D2D and EXD size F panels only. 10 Not available in D2L/EPL size D panels. D2D/EXD sizes C and D are only available withupto36circuits.Breaker Spaces TablesTable A. Maximum Number of Breaker Spaces D2L/EPL PanelsMaximum Number of Branch circuit Breaker spacesPanel sizeWith Main Lug OnlyWith Main BreakerTwo PoleThree PoleAvailable Main Breaker AmpacityAvailable with GFi, EPd Branch ProtectionB242221Up to 10012Yes11 C4240363936Up to 10012110 to 22513YesYesD424242Up to 22513YesTable B. Maximum Number of Breaker Spaces D2D/EXD PanelsMaximum Number of Branch circuit Breaker spacesPanel size
39
train
164,759
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf With Main Lug OnlyWith Main BreakerTwo PoleThree PoleAvailable Main Breaker AmpacityAvailable with GFi, EPd Branch Protection14B242221Up to 10012NoC424039Up to 10012NoDN/A4242Up to 22513NoF303030Up to 22513NoTable C. To Size Panels with GFI or EPD Branch BreakersMaximum Number of GFi or EPd BreakersPanel sizeWith Main Lug or Main Breakersingle PoleTwo PoleB2112
39
train
164,760
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 3030Up to 22513NoTable C. To Size Panels with GFI or EPD Branch BreakersMaximum Number of GFi or EPd BreakersPanel sizeWith Main Lug or Main Breakersingle PoleTwo PoleB2112(10 with 3 pole MCB, 11 with 2 pole MCB)Each factory sealed panel is equipped with 42 load wires for GFI/EPD breakers and any combination with standard branch breakers. Determine the total number of load wires required to complete your panel. You may not exceed 42 load wires.Load Wires RequiredSingle pole breaker=1Single pole GFI (or EPD) breaker=2Two pole breaker=2Two pole GFI (or EPD) breaker=3C2114Three pole breaker=3Maximum Total: 42 load wires (factory sealed)EPLDN PanelsMaximum Total: 82 load wires (non-factory sealed)DEPLDN only - can go up to 42 GFI or EPD circuits. EPLDN will accommodate up to 225 amp main breaker.11 ampshaveadedicatedlocationformainbreaker.SizeCorderedwithsuffix2M00or3M00areprovidedwith36branchcircuitsformaximumbreakerampacity. 12
39
train
164,766
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf All size B and C panels with main breaker rated up to 100 amps use a back-fed branch breaker. All size C and D panels with main breaker rated from 110 amps to 225Mainbreakersarechassismountedandbackfed.13Mainbreakersaremountedexternaltochassis.14GFI, EPD for D2D/EXD are not standard options. If required, please contact factory.EATON’s crOusE-hiNds PowerPlus™ Panelboards9Ordering Information D2L/EPL SeriesExample: D2LCS330G*28120*01115G-3M225-GBClass I, Division 2/Zone 2, Group B panel with: •240VAClightingpanelboard28singlepole20ampbranchbreakers1singlepole15ampbranchGFIbreaker225amp3polemaincircuitbreakerD2L C S 3 30G * 28 1 20 *Branch Breaker Ampere ratingPanel Typeinsert Asteriskd2L Div. 2/Zone 2EPLDiv. 1 & 2/ Zone 1 & 2Insert asterisk before each branch breaker series2020 ampsinsert AsteriskEnclosure sizeB24 circuit panelAlike Branch BreakersInsert asterisk before each branch breaker seriesc
39
train
164,767
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 42 circuit panel (36 circuit panel with main breaker greater than 100 amps)Insert quantity of alike branch breakersBranch Breaker Pole rating1Single pole breakerd42 circuit panel22 pole breaker33 pole breakerTerminal Enclosure MaterialPremium SolutionsStainless steel (Div. 2/Zone 2 panels only)ACast aluminumValue SolutionNNo terminal housing (non-factory sealed - Div. 1 & 2/ Zone 1 & 2)Panel Phase1Single phase3Three phaseBreaker spaces and Options (combined No. of circuits required)†Single pole breaker = 1 circuit2 pole breaker = 2 circuits3 pole breaker = 3 circuitsGFI = 1 additional circuit per breaker (suffix 'G')EPD = 1 additional circuit per breaker (suffix 'E')Ambient compensated breaker (+50°C) (suffix 'V')Example:(28) 1 pole 20 amp breakers= 28 circuits+ (1) 1 pole 15 amp GFI breaker= 2 circuitsTotal number of circuits= 30 (with 'G' for GFI circuit option)
39
train
164,768
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf †Even number of breaker spaces is required. For odd number of spaces, round up to next even number.10EATON’s crOusE-hiNds PowerPlus™ Panelboards01 1 15G 3 M 225 GBAlike Branch BreakersMain Breaker FollowsMain Breaker Amperage ratingInsert quantity of alike branch breakersSpace indicates that main breaker followsIndicates main breaker amperage ratingBranch Breaker Pole rating1Single pole breaker22 pole breaker33 pole breakerMain Breaker PolesMain breaker number of polesOptionsSee list of available options on page 8Main BreakerBranch Breaker Ampere rating15 = 15 ampsIndicates main breakerG = GFI breakers15G = GFI with 15 ampsEATON’s crOusE-hiNds PowerPlus™ Panelboards11Ordering Information D2D/EXD SeriesExample: D2DDS342V*42120-3M225-GB-GDBClass I, Division 2/Zone 2, Group B panel with:480Δ VAC power panelboard with 3 phase, 3 wire42singlepole20ampbranchbreakers225amp3polemaincircuitbreakerD2D D S 3 42 V * 42Panel Typed2d Div. 2/Zone 2
39
train
164,769
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf EXd Div. 1/Zone 1
39
train
164,770
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 3030Up to 22513NoTable C. To Size Panels with GFI or EPD Branch BreakersMaximum Number of GFi or EPd BreakersPanel sizeWith Main Lug or Main Breakersingle PoleTwo PoleB2112(10 with 3 pole MCB, 11 with 2 pole MCB)Each factory sealed panel is equipped with 42 load wires for GFI/EPD breakers and any combination with standard branch breakers. Determine the total number of load wires required to complete your panel. You may not exceed 42 load wires.Load Wires RequiredSingle pole breaker=1Single pole GFI (or EPD) breaker=2Two pole breaker=2Two pole GFI (or EPD) breaker=3C2114Three pole breaker=3Maximum Total: 42 load wires (factory sealed)EPLDN PanelsMaximum Total: 82 load wires (non-factory sealed)DEPLDN only - can go up to 42 GFI or EPD circuits. EPLDN will accommodate up to 225 amp main breaker.11 ampshaveadedicatedlocationformainbreaker.SizeCorderedwithsuffix2M00or3M00areprovidedwith36branchcircuitsformaximumbreakerampacity. 12
39
train
164,771
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf All size B and C panels with main breaker rated up to 100 amps use a back-fed branch breaker. All size C and D panels with main breaker rated from 110 amps to 225Mainbreakersarechassismountedandbackfed.13Mainbreakersaremountedexternaltochassis.14GFI, EPD for D2D/EXD are not standard options. If required, please contact factory.EATON’s crOusE-hiNds PowerPlus™ Panelboards9Ordering Information D2L/EPL SeriesExample: D2LCS330G*28120*01115G-3M225-GBClass I, Division 2/Zone 2, Group B panel with: •240VAClightingpanelboard28singlepole20ampbranchbreakers1singlepole15ampbranchGFIbreaker225amp3polemaincircuitbreakerD2L C S 3 30G * 28 1 20 *Branch Breaker Ampere ratingPanel Typeinsert Asteriskd2L Div. 2/Zone 2EPLDiv. 1 & 2/ Zone 1 & 2Insert asterisk before each branch breaker series2020 ampsinsert AsteriskEnclosure sizeB24 circuit panelAlike Branch BreakersInsert asterisk before each branch breaker seriesc
39
train
164,772
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 42 circuit panel (36 circuit panel with main breaker greater than 100 amps)Insert quantity of alike branch breakersBranch Breaker Pole rating1Single pole breakerd42 circuit panel22 pole breaker33 pole breakerTerminal Enclosure MaterialPremium SolutionsStainless steel (Div. 2/Zone 2 panels only)ACast aluminumValue SolutionNNo terminal housing (non-factory sealed - Div. 1 & 2/ Zone 1 & 2)Panel Phase1Single phase3Three phaseBreaker spaces and Options (combined No. of circuits required)†Single pole breaker = 1 circuit2 pole breaker = 2 circuits3 pole breaker = 3 circuitsGFI = 1 additional circuit per breaker (suffix 'G')EPD = 1 additional circuit per breaker (suffix 'E')Ambient compensated breaker (+50°C) (suffix 'V')Example:(28) 1 pole 20 amp breakers= 28 circuits+ (1) 1 pole 15 amp GFI breaker= 2 circuitsTotal number of circuits= 30 (with 'G' for GFI circuit option)
39
train
164,773
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf †Even number of breaker spaces is required. For odd number of spaces, round up to next even number.10EATON’s crOusE-hiNds PowerPlus™ Panelboards01 1 15G 3 M 225 GBAlike Branch BreakersMain Breaker FollowsMain Breaker Amperage ratingInsert quantity of alike branch breakersSpace indicates that main breaker followsIndicates main breaker amperage ratingBranch Breaker Pole rating1Single pole breaker22 pole breaker33 pole breakerMain Breaker PolesMain breaker number of polesOptionsSee list of available options on page 8Main BreakerBranch Breaker Ampere rating15 = 15 ampsIndicates main breakerG = GFI breakers15G = GFI with 15 ampsEATON’s crOusE-hiNds PowerPlus™ Panelboards11Ordering Information D2D/EXD SeriesExample: D2DDS342V*42120-3M225-GB-GDBClass I, Division 2/Zone 2, Group B panel with:480Δ VAC power panelboard with 3 phase, 3 wire42singlepole20ampbranchbreakers225amp3polemaincircuitbreakerD2D D S 3 42 V * 42Panel Typed2d Div. 2/Zone 2
39
train
164,774
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf EXd Div. 1/Zone 1
39
train
164,775
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 480Δ VAC power panelboard with 3 phase, 3 wire42singlepole20ampbranchbreakers225amp3polemaincircuitbreakerD2D D S 3 42 V * 42Panel Typed2d Div. 2/Zone 2EXd Div. 1/Zone 1Breaker OptionsVAmbient compensated (+50°C)Alike Branch BreakersInsert quantity of alike branch breakersEnclosure sizeinsert AsteriskBc24 circuit panel42 circuit panel without main breakerAsterisk denotes breaker characteristics followd42 circuit panel with main breakerF30 circuit panelTerminal Enclosure MaterialPremium SolutionsStainless steel (sizes B, C, D only)ACast aluminumValue SolutionNNo terminal housing (non-factory sealed)Panel Phase1Single phase3Three phaseBreaker spaces (combined No. of circuits required)†Example:Single pole breaker = 1 circuit2 pole breaker = 2 circuits3 pole breaker = 3 circuits†Even number of breaker spaces is required. For odd number of spaces, round up to next even number.12EATON’s crOusE-hiNds PowerPlus™ Panelboards
39
train
164,776
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Branch Breaker Pole rating1Single pole breaker22 pole breaker33 pole breakerBranch Breaker Ampere rating1515 amps2020 amps2525 amps3030 amps3535 amps4040 amps5050 amps6060 amps7070 amps1 20 3 M 225 GB GDBMain Breaker FollowsSpace indicates that main breaker followsMain BreakerIndicates main breakerMain Breaker Amperage ratingSize B: 15 to 100 ampsSizes C, D, F: 15 to 225 ampsMain Breaker PolesMain breaker number of polesOptionsGBGdBGroup B kit factory installedGDB frame breakers with 480Δ 3P 3W systemSee list of available options on page 8EATON’s crOusE-hiNds PowerPlus™ Panelboards13Dimensions D2L/EPL Series6.50 (165.1)6.50 (165.1)2.81 (71.4)4.66 (118.4)1-1/2" NPT 12 PLACES4.66 (118.4) 2.81 (71.4)5.10 (129.5) TYP.3.51 (89.2) TYP.3 1/2" NPT.92 (23.4)1/2" BOLT (M12)1.31 (33.3) TYP..50 (12.7)5.50 (139.7)1.83 (46.5)20.12 (511.0)CL3/8" BOLT (M9)12.93 (328.4) APPROXIMATE11.16 (283.5)
39
train
164,777
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 61.75 (1568.5)11.52 (292.6) APPROXIMATE48.63 (1235.2)29.50 (749.3)17.50 (444.5)6.00 (152.4)14.88 (377.8) TYP.5.75 (146.0)14.88 (377.8) TYP.Size C and D Panel* (with cast terminal housing)Size B Panel* (with stainless steel terminal housing)Stainless steel terminal housing for sizes B, C, D and F are the same. Cast aluminum terminal housing for sizes B, C and D are the same.Note: Value series non-factory sealed EPL*N panel dimensions are the breaker housing only and use standard entries shown on cast terminal housing.14EATON’s crOusE-hiNds PowerPlus™ Panelboards4.00 (101.6)3 1/2" NPT ALTERNATE FEED OPTION (SUFFIX 'A') ONLYDimensions D2D/EXD Series2.81 71.46.50 [165.1]4.66 [118.4]1-1/2" NPT 12 PLACES6.50 [165.1] 4.66 [118.4] 2.81 71.4.92 [23.4]1.31 [33.3]5.10 [129.5] TYP.3.51 [89.2] TYP.3 1/2" NPT1.83 [46.5]20.12 [511.2].50 [12.7]5.50 [139.7]11.16 [283.4]62.15 [1578.5]13.49 [342.7] APPROXIMATE48.36 [1228.3]11.37 [288.9] APPROXIMATE
39
train
164,778
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 28.25 [717.6]17.25 [438.2]6.17 [156.7]6.82 [173.3]21.88 [555.6]21.88 [555.6]Size C and D Panel† (with cast aluminum terminal housing)Size B Panel† (with stainless steel terminal housing)Size F Panel†Stainless steel terminal housing for all sizes are the same. Cast aluminum terminal housing option for sizes C and D panels listed above are standard.Note: Value series non-factory sealed EXD*N panel dimensions are the breaker housing only and use standard entries shown on cast terminal housing.EATON’s crOusE-hiNds PowerPlus™ Panelboards4.00 [101.5]3 1/2" NPT ALTERNATE FEED OPTION (SUFFIX 'A') ONLY15U.S. (Global Headquarters): Eaton's Crouse-Hinds Business1201 Wolf Street Syracuse,NY13208(866)764-5454 FAX:(315)477-5179 FAX Orders Only: (866)653-0640crouse.customerctr@ cooperindustries.comFor more information:
39
train
164,779
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 480Δ VAC power panelboard with 3 phase, 3 wire42singlepole20ampbranchbreakers225amp3polemaincircuitbreakerD2D D S 3 42 V * 42Panel Typed2d Div. 2/Zone 2EXd Div. 1/Zone 1Breaker OptionsVAmbient compensated (+50°C)Alike Branch BreakersInsert quantity of alike branch breakersEnclosure sizeinsert AsteriskBc24 circuit panel42 circuit panel without main breakerAsterisk denotes breaker characteristics followd42 circuit panel with main breakerF30 circuit panelTerminal Enclosure MaterialPremium SolutionsStainless steel (sizes B, C, D only)ACast aluminumValue SolutionNNo terminal housing (non-factory sealed)Panel Phase1Single phase3Three phaseBreaker spaces (combined No. of circuits required)†Example:Single pole breaker = 1 circuit2 pole breaker = 2 circuits3 pole breaker = 3 circuits†Even number of breaker spaces is required. For odd number of spaces, round up to next even number.12EATON’s crOusE-hiNds PowerPlus™ Panelboards
39
train
164,780
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Branch Breaker Pole rating1Single pole breaker22 pole breaker33 pole breakerBranch Breaker Ampere rating1515 amps2020 amps2525 amps3030 amps3535 amps4040 amps5050 amps6060 amps7070 amps1 20 3 M 225 GB GDBMain Breaker FollowsSpace indicates that main breaker followsMain BreakerIndicates main breakerMain Breaker Amperage ratingSize B: 15 to 100 ampsSizes C, D, F: 15 to 225 ampsMain Breaker PolesMain breaker number of polesOptionsGBGdBGroup B kit factory installedGDB frame breakers with 480Δ 3P 3W systemSee list of available options on page 8EATON’s crOusE-hiNds PowerPlus™ Panelboards13Dimensions D2L/EPL Series6.50 (165.1)6.50 (165.1)2.81 (71.4)4.66 (118.4)1-1/2" NPT 12 PLACES4.66 (118.4) 2.81 (71.4)5.10 (129.5) TYP.3.51 (89.2) TYP.3 1/2" NPT.92 (23.4)1/2" BOLT (M12)1.31 (33.3) TYP..50 (12.7)5.50 (139.7)1.83 (46.5)20.12 (511.0)CL3/8" BOLT (M9)12.93 (328.4) APPROXIMATE11.16 (283.5)
39
train
164,781
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 61.75 (1568.5)11.52 (292.6) APPROXIMATE48.63 (1235.2)29.50 (749.3)17.50 (444.5)6.00 (152.4)14.88 (377.8) TYP.5.75 (146.0)14.88 (377.8) TYP.Size C and D Panel* (with cast terminal housing)Size B Panel* (with stainless steel terminal housing)Stainless steel terminal housing for sizes B, C, D and F are the same. Cast aluminum terminal housing for sizes B, C and D are the same.Note: Value series non-factory sealed EPL*N panel dimensions are the breaker housing only and use standard entries shown on cast terminal housing.14EATON’s crOusE-hiNds PowerPlus™ Panelboards4.00 (101.6)3 1/2" NPT ALTERNATE FEED OPTION (SUFFIX 'A') ONLYDimensions D2D/EXD Series2.81 71.46.50 [165.1]4.66 [118.4]1-1/2" NPT 12 PLACES6.50 [165.1] 4.66 [118.4] 2.81 71.4.92 [23.4]1.31 [33.3]5.10 [129.5] TYP.3.51 [89.2] TYP.3 1/2" NPT1.83 [46.5]20.12 [511.2].50 [12.7]5.50 [139.7]11.16 [283.4]62.15 [1578.5]13.49 [342.7] APPROXIMATE48.36 [1228.3]11.37 [288.9] APPROXIMATE
39
train
164,782
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 28.25 [717.6]17.25 [438.2]6.17 [156.7]6.82 [173.3]21.88 [555.6]21.88 [555.6]Size C and D Panel† (with cast aluminum terminal housing)Size B Panel† (with stainless steel terminal housing)Size F Panel†Stainless steel terminal housing for all sizes are the same. Cast aluminum terminal housing option for sizes C and D panels listed above are standard.Note: Value series non-factory sealed EXD*N panel dimensions are the breaker housing only and use standard entries shown on cast terminal housing.EATON’s crOusE-hiNds PowerPlus™ Panelboards4.00 [101.5]3 1/2" NPT ALTERNATE FEED OPTION (SUFFIX 'A') ONLY15U.S. (Global Headquarters): Eaton's Crouse-Hinds Business1201 Wolf Street Syracuse,NY13208(866)764-5454 FAX:(315)477-5179 FAX Orders Only: (866)653-0640crouse.customerctr@ cooperindustries.comFor more information:
39
train
164,783
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 480Δ VAC power panelboard with 3 phase, 3 wire42singlepole20ampbranchbreakers225amp3polemaincircuitbreakerD2D D S 3 42 V * 42Panel Typed2d Div. 2/Zone 2EXd Div. 1/Zone 1Breaker OptionsVAmbient compensated (+50°C)Alike Branch BreakersInsert quantity of alike branch breakersEnclosure sizeinsert AsteriskBc24 circuit panel42 circuit panel without main breakerAsterisk denotes breaker characteristics followd42 circuit panel with main breakerF30 circuit panelTerminal Enclosure MaterialPremium SolutionsStainless steel (sizes B, C, D only)ACast aluminumValue SolutionNNo terminal housing (non-factory sealed)Panel Phase1Single phase3Three phaseBreaker spaces (combined No. of circuits required)†Example:Single pole breaker = 1 circuit2 pole breaker = 2 circuits3 pole breaker = 3 circuits†Even number of breaker spaces is required. For odd number of spaces, round up to next even number.12EATON’s crOusE-hiNds PowerPlus™ Panelboards
39
train
164,784
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf Branch Breaker Pole rating1Single pole breaker22 pole breaker33 pole breakerBranch Breaker Ampere rating1515 amps2020 amps2525 amps3030 amps3535 amps4040 amps5050 amps6060 amps7070 amps1 20 3 M 225 GB GDBMain Breaker FollowsSpace indicates that main breaker followsMain BreakerIndicates main breakerMain Breaker Amperage ratingSize B: 15 to 100 ampsSizes C, D, F: 15 to 225 ampsMain Breaker PolesMain breaker number of polesOptionsGBGdBGroup B kit factory installedGDB frame breakers with 480Δ 3P 3W systemSee list of available options on page 8EATON’s crOusE-hiNds PowerPlus™ Panelboards13Dimensions D2L/EPL Series6.50 (165.1)6.50 (165.1)2.81 (71.4)4.66 (118.4)1-1/2" NPT 12 PLACES4.66 (118.4) 2.81 (71.4)5.10 (129.5) TYP.3.51 (89.2) TYP.3 1/2" NPT.92 (23.4)1/2" BOLT (M12)1.31 (33.3) TYP..50 (12.7)5.50 (139.7)1.83 (46.5)20.12 (511.0)CL3/8" BOLT (M9)12.93 (328.4) APPROXIMATE11.16 (283.5)
39
train
164,785
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 61.75 (1568.5)11.52 (292.6) APPROXIMATE48.63 (1235.2)29.50 (749.3)17.50 (444.5)6.00 (152.4)14.88 (377.8) TYP.5.75 (146.0)14.88 (377.8) TYP.Size C and D Panel* (with cast terminal housing)Size B Panel* (with stainless steel terminal housing)Stainless steel terminal housing for sizes B, C, D and F are the same. Cast aluminum terminal housing for sizes B, C and D are the same.Note: Value series non-factory sealed EPL*N panel dimensions are the breaker housing only and use standard entries shown on cast terminal housing.14EATON’s crOusE-hiNds PowerPlus™ Panelboards4.00 (101.6)3 1/2" NPT ALTERNATE FEED OPTION (SUFFIX 'A') ONLYDimensions D2D/EXD Series2.81 71.46.50 [165.1]4.66 [118.4]1-1/2" NPT 12 PLACES6.50 [165.1] 4.66 [118.4] 2.81 71.4.92 [23.4]1.31 [33.3]5.10 [129.5] TYP.3.51 [89.2] TYP.3 1/2" NPT1.83 [46.5]20.12 [511.2].50 [12.7]5.50 [139.7]11.16 [283.4]62.15 [1578.5]13.49 [342.7] APPROXIMATE48.36 [1228.3]11.37 [288.9] APPROXIMATE
39
train
164,786
Title: crouse-hinds-powerplus-panelboards-brochure-brochure.pdf 28.25 [717.6]17.25 [438.2]6.17 [156.7]6.82 [173.3]21.88 [555.6]21.88 [555.6]Size C and D Panel† (with cast aluminum terminal housing)Size B Panel† (with stainless steel terminal housing)Size F Panel†Stainless steel terminal housing for all sizes are the same. Cast aluminum terminal housing option for sizes C and D panels listed above are standard.Note: Value series non-factory sealed EXD*N panel dimensions are the breaker housing only and use standard entries shown on cast terminal housing.EATON’s crOusE-hiNds PowerPlus™ Panelboards4.00 [101.5]3 1/2" NPT ALTERNATE FEED OPTION (SUFFIX 'A') ONLY15U.S. (Global Headquarters): Eaton's Crouse-Hinds Business1201 Wolf Street Syracuse,NY13208(866)764-5454 FAX:(315)477-5179 FAX Orders Only: (866)653-0640crouse.customerctr@ cooperindustries.comFor more information: