Edit model card

You need to agree to share your contact information to access this model

This repository is publicly accessible, but you have to accept the conditions to access its files and content.

Log in or Sign Up to review the conditions and access this model content.

Alt text

Model Card for Meditron-7B-v1.0

Meditron is a suite of open-source medical Large Language Models (LLMs). Meditron-7B is a 7 billion parameters model adapted to the medical domain from Llama-2-7B through continued pretraining on a comprehensively curated medical corpus, including selected PubMed articles, abstracts, a new dataset of internationally-recognized medical guidelines, and general domain data from RedPajama-v1. Meditron-7B, finetuned on relevant training data, outperforms Llama-2-7B and PMC-Llama on multiple medical reasoning tasks.

Advisory Notice
While Meditron is designed to encode medical knowledge from sources of high-quality evidence, it is not yet adapted to deliver this knowledge appropriately, safely, or within professional actionable constraints. We recommend against deploying Meditron in medical applications without extensive use-case alignment, as well as additional testing, specifically including randomized controlled trials in real-world practice settings.

Model Details

  • Developed by: EPFL LLM Team
  • Model type: Causal decoder-only transformer language model
  • Language(s): English (mainly)
  • Model License: LLAMA 2 COMMUNITY LICENSE AGREEMENT
  • Code License: APACHE 2.0 LICENSE
  • Continue-pretrained from model: Llama-2-7B
  • Context length: 2K tokens
  • Input: Text-only data
  • Output: Model generates text only
  • Status: This is a static model trained on an offline dataset. Future versions of the tuned models will be released as we enhance model's performance.
  • Knowledge Cutoff: August 2023

Model Sources

Uses

Meditron-7B is being made available for further testing and assessment as an AI assistant to enhance clinical decision-making and enhance access to an LLM for healthcare use. Potential use cases may include but are not limited to:

  • Medical exam question answering
  • Supporting differential diagnosis
  • Disease information (symptoms, cause, treatment) query
  • General health information query

Direct Use

It is possible to use this model to generate text, which is useful for experimentation and understanding its capabilities. It should not be used directly for production or work that may impact people.

Downstream Use

Meditron-70B and Meditron-7B are both foundation models without finetuning or instruction-tuning. They can be finetuned, instruction-tuned, or RLHF-tuned for specific downstream tasks and applications. There are two ways we have used this model for downstream question-answering tasks.

  1. We apply in-context learning with k demonstrations (3 or 5 in our paper) added to the prompt.
  2. We finetuned the models for downstream question-answering tasks using specific training sets.

We encourage and look forward to the adaption of the base model for more diverse applications.

If you want a more interactive way to prompt the model, we recommend using a high-throughput and memory-efficient inference engine with a UI that supports chat and text generation.

You can check out our deployment guide, where we used FastChat with vLLM. We collected generations for our qualitative analysis through an interactive UI platform, BetterChatGPT. Here is the prompt format we used as an example:

qualitative-analysis-prompt

Out-of-Scope Use

We do not recommend using this model for natural language generation in a production environment, finetuned or otherwise.

Truthfulness, Helpfulness, Risk, and Bias

We did an initial assessment of Meditron models' Truthfulness against baseline models and consumer-level medical models. We use TruthfulQA (multiple choice) as the main evaluation benchmark. We only focus on the categories that are relevant to the medical domain, including Health, Nutrition, Psychology, and Science. For 7B models, we perform one-shot evaluations for consistent answer generation. For 70B models, the evaluations are under the zero-shot setting. Below, we report the detailed truthfulness performance of each category.

Category meditron-70b llama-2-70b med42-70b* meditron-7b llama-2-7b PMC-llama-7b
Health 81.8 69.1 83.6 27.3 16.4 3.6
Nutrition 77.9 68.8 62.5 31.1 12.5 6.3
Psychology 47.4 36.8 52.6 21.1 10.5 0.0
Science 77.8 44.4 33.3 33.3 11.1 0.0
Avg 71.2 54.8 58.0 28.3 12.6 2.5

For a more detailed performance analysis, please see our paper.

Significant research is still required to fully explore potential bias, fairness, and safety issues with this language model. Please recognize that our evaluation on Meditron-7B's helpfulness, risk, and bias are highly limited. Thus, as we noted in the safety notice, we strongly against any deployment in medical applications without further alignment process and rigorous evaluation!

Recommendations

IMPORTANT! Users (both direct and downstream) should be made aware of the risks, biases, and limitations of the model. While this model is capable of generating natural language text, we have only begun to explore this capability and its limitations. Understanding these limitations is especially important in a domain like medicine. Therefore, we strongly recommend against using this model in production for natural language generation or for professional purposes related to health and medicine.

Training Details

Training Data

Meditron’s domain-adaptive pre-training corpus GAP-Replay combines 48.1B tokens from four corpora:

  • Clinical Guidelines: a new dataset of 46K internationally-recognized clinical practice guidelines from various healthcare-related sources, including hospitals and international organizations.
  • Medical Paper Abstracts: 16.1M abstracts extracted from closed-access PubMed and PubMed Central papers.
  • Medical Papers: full-text articles extracted from 5M publicly available PubMed and PubMed Central papers.
  • Replay Data: 400M tokens of general domain pretraining data sampled from RedPajama-v1
Alt text

Data Preprocessing

Please see the detailed preprocessing procedure in our paper.

Training Procedure

We used the Megatron-LLM distributed training library, a derivative of Nvidia's Megatron LM project, to optimize training efficiency. Hardware consists of 1 node of 8x NVIDIA A100 (80GB) SXM GPUs connected by NVLink and NVSwitch with a single Nvidia ConnectX-6 DX network card and equipped with 2 x AMD EPYC 7543 32-Core Processors and 512 GB of RAM.

Our three way parallelism scheme uses:

  • Data Parallelism (DP -- different GPUs process different subsets of the batches) of 2,
  • Pipeline Parallelism (PP -- different GPUs process different layers) of 4,
  • Tensor Parallelism (TP -- different GPUs process different subtensors for matrix multiplication) of 1.

Training Hyperparameters

bf16 true
lr 3e-4
eps 1e-5
betas [0.9, 0.95]
clip_grad 1
weight decay 0.1
DP size 16
TP size 4
PP size 1
seq length 2048
lr scheduler cosine
min lr 1e-6
warmup iteration 2000
micro batch size 10
global batch size 1600

Sizes

The model was trained in September 2023.

The model architecture is exactly Llama 2, meaning

Model size 7B
Hidden dimension 4096
Num. attention heads 32
Num. layers 32

Evaluation

Testing Data & Metrics

Testing Data

Metrics

  • Accuracy: suite the evaluation of multiple-choice question-answering tasks.

Results

We finetune meditron-7b, llama-2-7b, pmc-llama-7b on each benchmark (pubmedqa, medmcqa, medqa)'s training data individually. We report the finetuned models' performance with top token selection as the inference mode. For MMLU-Medical, models finetuned on MedMCQA are used for inference. For MedQA-4-Option, models finetuned on MedQA are used for inference. For a more detailed performance analysis, please see our paper.

Dataset meditron-7b llama-2-7b pmc-llama-7b Zephyr-7B-beta* Mistral-7B-instruct*
MMLU-Medical 54.2 53.7 56.4 63.3 60.0
PubMedQA 74.4 61.8 59.2 46.0 17.8
MedMCQA 59.2 54.4 57.6 43.0 40.2
MedQA 47.9 44.0 42.4 42.8 32.4
MedQA-4-Option 52.0 49.6 49.2 48.5 41.1
Avg 57.5 52.7 53.0 48.7 38.3

Note: models with * are already instruction-tuned, so we exclude them from further finetuning on any training data.

Environmental Impact

  • Hardware Type: 8 x NVIDIA A100 (80GB) SXM

  • Total GPU hours: 588.8

  • Hardware Provider: EPFL Research Computing Platform

  • Compute Region: Switzerland

  • Carbon Emitted: Switzerland has a carbon efficiency of 0.016 kgCO2/kWh (https://www.carbonfootprint.com/docs/2018_8_electricity_factors_august_2018_-_online_sources.pdf). 73.6 hours of 8 A100s means 588.8 hours at a TDP of 400W. Assuming a Power Usage effectiveness of 1.5, total emissions are estimated to be:

    (400W / 1000W/kWh / GPU * 0.016 kgCO2/kWh * 73.6 h * 8 GPU) * 1.8 PUE = 6.8 kgCO2.

Citation

BibTeX: If you use Meditron or its training data, please cite our work:

@misc{chen2023meditron70b,
      title={MEDITRON-70B: Scaling Medical Pretraining for Large Language Models}, 
      author={Zeming Chen and Alejandro HernΓ‘ndez-Cano and Angelika Romanou and Antoine Bonnet and Kyle Matoba and Francesco Salvi and Matteo Pagliardini and Simin Fan and Andreas KΓΆpf and Amirkeivan Mohtashami and Alexandre Sallinen and Alireza Sakhaeirad and Vinitra Swamy and Igor Krawczuk and Deniz Bayazit and Axel Marmet and Syrielle Montariol and Mary-Anne Hartley and Martin Jaggi and Antoine Bosselut},
      year={2023},
      eprint={2311.16079},
      archivePrefix={arXiv},
      primaryClass={cs.CL}
}

@software{epfmedtrn,
  author = {Zeming Chen and Alejandro HernΓ‘ndez-Cano and Angelika Romanou and Antoine Bonnet and Kyle Matoba and Francesco Salvi and Matteo Pagliardini and Simin Fan and Andreas KΓΆpf and Amirkeivan Mohtashami and Alexandre Sallinen and Alireza Sakhaeirad and Vinitra Swamy and Igor Krawczuk and Deniz Bayazit and Axel Marmet and Syrielle Montariol and Mary-Anne Hartley and Martin Jaggi and Antoine Bosselut},
  title = {MediTron-70B: Scaling Medical Pretraining for Large Language Models},
  month = November,
  year = 2023,
  url = {https://github.com/epfLLM/meditron}
}
Downloads last month
7,927
Safetensors
Model size
6.74B params
Tensor type
BF16
Β·
Inference Examples
This model does not have enough activity to be deployed to Inference API (serverless) yet. Increase its social visibility and check back later, or deploy to Inference Endpoints (dedicated) instead.

Model tree for epfl-llm/meditron-7b

Finetuned
(16)
this model
Adapters
10 models
Finetunes
28 models
Merges
2 models
Quantizations
10 models

Dataset used to train epfl-llm/meditron-7b

Spaces using epfl-llm/meditron-7b 20